1,582 research outputs found

    Conduction States with Vanishing Dimerization in Pt Nanowires on Ge(001) Observed with Scanning Tunneling Microscopy

    Full text link
    The low-energy electronic properties of one-dimensional nanowires formed by Pt atoms on Ge(001) are studied with scanning tunneling microscopy down to the millivolt-regime. The chain structure exhibits various dimerized elements at high tunneling bias, indicative of a substrate bonding origin rather than a charge density wave. Unexpectedly, this dimerization becomes vanishingly small when imaging energy windows close to the Fermi level with adequately low tunneling currents. Evenly spaced nanowire atoms emerge which are found to represent conduction states. Implications for the metallicity of the chains are discussed.Comment: 4 pages, 4 figure

    Renormalization-group study of a magnetic impurity in a Luttinger liquid

    Full text link
    A generalized Anderson model for a magnetic impurity in an interacting one-dimensional electron gas is studied via a mapping onto a classical Coulomb gas. For weak potential scattering, the local-moment parameter regime expands as repulsive bulk interactions become stronger, but the Kondo scale for the quenching of the impurity moment varies nonmonotonically. There also exist two regimes dominated by backward potential scattering: one in which the impurity is nonmagnetic, and another in which an unquenched local moment survives down to very low temperatures.Comment: REVTeX, 4 pages, 3 epsf-embedded EPS figure

    Phase diagram of an asymmetric spin ladder

    Full text link
    We investigate an asymmetric zig-zag spin ladder with different exchange integrals on both legs using bosonization and renormalization group. When the leg exchange integrals and frustration both are sufficiently small, renormalization group analysis shows that the Heisenberg critical point flows to an intermediate-coupling fixed point with gapless excitations and a vanishing spin velocity. When they are large, a spin gap opens and a dimer liquid is realized. Here, we find a continuous manifold of Hamiltonians with dimer product ground states, interpolating between the Majumdar-Ghosh and sawtooth spin-chain model.Comment: 4 pages, 2 EPS figures, to be published in PR

    Vacuum properties of a Non-Local Thirring-Like Model

    Get PDF
    We use path-integral methods to analyze the vacuum properties of a recently proposed extension of the Thirring model in which the interaction between fermionic currents is non-local. We calculate the exact ground state wave functional of the model for any bilocal potential, and also study its long-distance behavior. We show that the ground state wave functional has a general factored Jastrow form. We also find that it posess an interesting symmetry involving the interchange of density-density and current-current interactions.Comment: 25 pages, latex, no figure

    Inferior vena cava revisited - Real-time flow MRI of respiratory maneuvers.

    Get PDF
    Recent MRI studies of blood flow in the inferior vena cava (IVC) resulted in findings which are inconsistent with earlier observations by invasive procedures - most likely because ECG-gated MRI techniques are unable to resolve dynamic adjustments due to respiration. The purpose of this work was to apply real-time phase-contrast MRI at 50 ms resolution to re-evaluate IVC flow in response to normal and deep breathing as well as breath holding and Valsalva maneuver (11 young healthy subjects). Real-time flow MRI relied on highly undersampled radial gradient-echo sequences and a model-based nonlinear inverse reconstruction. A frequency analysis of the predominant pulsatility classified IVC flow in individual subjects as "cardiac", "respiratory" or "mixed" type. Peak flow velocities during free breathing ranged from 30 to 58 cm s(-1), while flow rates varied from 15 to 37 ml s(-1). The subject-specific IVC flow pattern persists during deep breathing although the enhanced respiratory influence may shift subjects form "cardiac" to "mixed" or from "mixed" to "respiratory" type. Peak velocities increased relative to normal breathing but led to similar flow rates of 16 to 34 ml s(-1). Inspiration during deep breathing elicited brief periods of flow reversal in all subjects with mean peak velocities of -21 cm s(-1). The observation of only mildly flattened parabolic velocity distributions within the IVC indicated mostly laminar flow. Breath holding reduced blood flow velocities and rates by more than 40% on average, while Valsalva maneuvers completely abolished venous return. In conclusion, IVC blood flow is dominated by the acquired respiratory behavior of individual subjects and its pressure-induced alterations relative to cardiac pulsation. The responses to breath holding and Valsalva maneuver are in full agreement with previous invasive observations of reduced or even ceased flow, respectively

    Diffusion-weighted magnetic resonance imaging (MRI) without susceptibility artifacts: single-shot stimulated echo acquisition mode (STEAM) MRI with iterative reconstruction and spatial regularization

    Get PDF
    This work describes a new method for diffusion-weighted (DW) magnetic resonance imaging (MRI) without susceptibility artifacts. The technique combines a DW spin-echo module and a single-shot stimulated echo acquisition mode (STEAM) MRI readout with undersampled radial trajectories and covers a volume by a gapless series of cross-sectional slices. In a first step, optimal coil sensitivities for all slices are obtained from a series of non-DW acquisitions by nonlinear inverse reconstruction with regularization to the image and coil sensitivities of a directly neighboring slice. In a second step, these coil sensitivities are used to compute all series of non-DW and DW images by linear inverse reconstruction with spatial regularization to a neighboring image. Proof-of-principle applications to the brain (51 sections) and prostate (31 sections) of healthy subjects were realized for a protocol with two b-values and 6 gradient directions at 3 T. Including averaging the measuring times for studies of the brain at 1.0×1.0×3.0 mm3 resolution (b =1,000 s mm−2) and prostate at 1.4×1.4×3.0 mm3 resolution (b =600 s mm-2) were 2.5 min and 4.5 min, respectively. All reconstructions were accomplished online with use of a multi-GPU computer integrated into the MRI system. The resulting non-DW images, mean DW images averaged across directions and maps of the apparent diffusion coefficient confirm the absence of geometric distortions or false signal alterations and demonstrate diagnostic image quality. The novel method for DW STEAM MRI of a volume without susceptibility artifacts warrants extended clinical trials

    Real-time magnetic resonance imaging: Radial gradient-echo sequences with nonlinear inverse reconstruction.

    Get PDF
    Objective The aim of this study is to evaluate a real-time magnetic resonance imaging (MRI) method that not only promises high spatiotemporal resolution but also practical robustness in a wide range of scientific and clinical applications. Materials and Methods The proposed method relies on highly undersampled gradient-echo sequences with radial encoding schemes. The serial image reconstruction process solves the true mathematical task that emerges as a nonlinear inverse problem with the complex image and all coil sensitivity maps as unknowns. Extensions to model-based reconstructions for quantitative parametric mapping further increase the number of unknowns, for example, by adding parameters for phase-contrast flow or T1 relaxation. In all cases, an iterative numerical solution that minimizes a respective cost function is achieved with use of the iteratively regularized Gauss-Newton method. Convergence is supported by regularization, for example, to the preceding frame, whereas temporal fidelity is ensured by downsizing the regularization strength in comparison to the data consistency term in each iterative step. Practical implementations of highly parallelized algorithms are realized on a computer with multiple graphical processing units. It is "invisibly" integrated into a commercial 3-T MRI system to allow for conventional usage and to provide online reconstruction, display, and storage of regular DICOM image series. Results Depending on the application, the proposed method offers serial imaging, that is, the recording of MRI movies, with variable spatial resolution and up to 100 frames per second (fps)-corresponding to 10 milliseconds image acquisition times. For example, movements of the temporomandibular joint during opening and closing of the mouth are visualized with use of simultaneous dual-slice movies of both joints at 2 x 10 fps (50 milliseconds per frame). Cardiac function may be studied at 30 to 50 fps (33.3 to 20 milliseconds), whereas articulation processes typically require 50 fps (20 milliseconds) or orthogonal dual-slice acquisitions at 2 x 25 fps (20 milliseconds). Methodological extensions to model-based reconstructions achieve improved quantitative mapping of flow velocities and T1 relaxation times in a variety of clinical scenarios. Conclusions Real-time gradient-echo MRI with extreme radial undersampling and nonlinear inverse reconstruction allows for direct monitoring of arbitrary physiological processes and body functions. In many cases, pertinent applications offer hitherto impossible clinical studies (eg, of high-resolution swallowing dynamics) or bear the potential to replace existing MRI procedures (eg, electrocardiogram-gated cardiac examinations). As a consequence, many novel opportunities will require a change of paradigm in MRI-based radiology. At this stage, extended clinical trials are needed

    Interpretation of Photoemission Spectra of (TaSe4)2I as Evidence of Charge Density Wave Fluctuations

    Full text link
    The competition between different and unusual effects in quasi-one-dimensional conductors makes the direct interpretation of experimental measurements of these materials both difficult and interesting. We consider evidence for the existence of large charge-density-wave fluctuations in the conducting phase of the Peierls insulator (TaSe4)2I, by comparing the predictions of a simple Lee, Rice and Anderson theory for such a system with recent angle-resolved photoemission spectra. The agreement obtained suggests that many of the unusual features of these spectra may be explained in this way. This view of the system is contrasted with the behaviour expected of a Luttinger liquid.Comment: Archive copy of published paper. 19 pages, 12 figures, uses IOP macro
    • …
    corecore